Harmonic Power Factor Compensation Power Quality Improvement Economical Solution

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Beijing
Validity to: Long-term effective
Last update: 2018-02-21 15:34
Browse the number: 106
inquiry
Company Profile
 
 
Product details
Harmonic Power Factor Compensation Power Quality Improvement Economical Solution


1. Power quality improvement economical solution 

In practical application, the traditional passive filter capacitor compensation and passive filter are commonly used in quality management, Green Power APF and SVG can work together with traditional method, realize more reliable, more convenient and more economic compensation, which is our unique solution for power quality improvement.


2. Capacitor reactive power compensation+SVG

The traditional reactive power compensation adopt slow switching device for capacitor switching, there is problem of differential compensation, poor compensation accuracy, slow response speed. SVG adopts high speed switching device to generate the compensation current, without the problem of compensation accuracy and slow response.

For low cost considerations, most or half compensation is compensated by capacitor groups, the remaining is completed by SVG, which ensure smooth compensation, also low cost, namely SVG+C method.
 

3. Dynamic reactive power compensation method comparison

Name

TSC

SVG+C

SVG

Output reactive power

Group switching, rough compensation

Linear output, accurate compensation

Linear output, accurate compensation

Compensating effect

0.9 above

0.99, could be partially sensitive

0.99, full resistive to full capacitive

Total response time

>100ms

>30ms

<10ms

Filter ability

no

Partial specified harmonic

2-13 harmonic

Three-phase unbalance

no

Obvious effect

Thoroughly solve three-phase unbalanced

Support voltage

no

Partial capacity support voltage

Full power support voltage

Price

Relative low

The cost is little higher than TSC

Higher than TSC


4. Traditional Passive filter+APF

The traditional harmonic compensation is the passive filter of the capacitance and resistance, which has the disadvantages of low compensation precision, slow response, poor reliability and limited harmonic compensation.

APF adopts high speed switching device to generate the compensation current, there is no compensation accuracy problem, and also has fast response.

For low cost considerations, use passive filter to compensate main low harmonics, the remaining harmonic is compensated by APF, to ensure smooth compensation, and also with low cost, that is APF+LC.

In the combined compensation, APF compensated harmonic should avoid LC compensated harmonic, otherwise the compensation has no effect.


5. Advantages of GP APF/SVG+traditional compensation

More reliable

Can be in parallel with any form of C/TSC/LC.

In practical application, users with traditional power quality management have a variety of forms, a pure capacitor C, series connection 0.4%~14% reactor TSC, passive filter LC, GP power quality products adopt the methods such as suppression of resonance peak, shielding specified harmonic output etc., and ensure reliable running when parallel connection with any passive devices. Especially in parallel with the pure capacitor C, the suppression of resonance technology reaches international advanced level.

More convenient

Can coordinate with any C/TSC/LC, regardless the main line at any location, CT at any location, can be reliable operation. Does not need to know the current of C/TSC/LC, and L can take from 0 to any value.


SVG is close to the load side, can compensate low harmonics and three-phase unbalance, but compensation for reactive power, due to the faster speed of SVG, will precede the action of capacitors, therefore when SVG for reactive power compensation occasions, recommend SVG near the grid side. 

APF/SVG and LC position relation


Main line position

Active CT

  Sampling point

Passive form

Active near grid side

  Passive close to load side

Active close to load side

  Passive close to grid side

APF

Effective compensation

Effective compensation

Optional power grid side or load side

L could be 0~ arbitrary value

  C can be any switching form

SVG

Effective compensation

Can effectively compensate low degree harmonics and 3 phase unbalance, but with the capacitor to compensate reactive power is not economical

Note

active and passive parallel, APF should avoid passive filter compensating harmonic frequency.

More economical

SVG can be parallel connected with capacitor with same size, to achieve maximum single cabinet power density, lower cost, more economical. The compensation effect and the response speed are all equal to the effect of reactive power compensation using SVG.

Can also be used as a component, integrated in power distribution cabinet with other TSC/LC, to increase power density. We can provide custom solutions of integrating in distribution cabinet with other suppliers LC.


Looking for harmonic power factor compensation power quality improvement economical solution? Green Power Technology is one of the professional manufacturers and suppliers. We have been dedicated to this field for over 20 years and already exported products to India, USA, Germany, etc. Equipped with a productive factory, we warmly welcome you to buy our high quality products made in China at competitive price or try our customized service.

http://www.gprectifier.com/