10 Inch Flanged Gate Valve
The 10-inch flange gate valve is closed, and the sealing surface can only be sealed. In other words, the sealing surface of the gate can be pressed to the other side to ensure tightness.
10 Inch Flanged Gate Valve Design Description:
- external thread and yoke
- pressure seal
- rising stem
-Gear operator, electric actuator, pneumatic actuator, bypass, locking device, sprocket, extension rod, and hood to meet customer requirements.
- flange and docking welding brake valve
- Can provide different types of disks
- Low torque design, surface light slide rod.
Advantage:
1. The same straight-through structure and flow channel greatly reduce the fluidity coefficient and energy loss, significantly improve the life and performance of the valve.
2. The valve uses a pressure self-sealing structure and has good sealing performance.
3. The sealing surface of the gate valve and the valve seat is made of hard alloy surface, with good wear resistance, high temperature resistance, corrosion resistance, and wear resistance.
4. Surface nitriding resistance and good wear resistance of the stem.
5. The structure of the hoist can be designed as a single layer, a double layer and a parallel.
Brand |
GangYe |
Valve Material |
Gangye provide cast steel, stainless steel, special alloy steel, Chrome-moly steel |
Valve Type |
Rising Stem, PSB, FB, OS&Y |
Valve Test |
100% quantity tested before delivery |
Valve Guarantee |
18 months after shipments and 12 months after installed |
Valve Structure |
Gate Valve |
Valve Delivery |
15 - 30 days |
Valve Sample |
Sample Available by Gangye Valve |
Valve Color |
Customer request |
Valve Packing |
Plywood Case for Gate Valve |
MOQ |
1 Set |
Valve Certificate |
API6D/ CE/ ISO9001/ ISO14001 |
Place of Origin |
Zhejiang, China (Mainland) |
Delivery Detail: |
Shipped in 15-30 days after payment |
Port |
Shanghai Or Ningbo |
Payment Terms |
L/C, T/T, Western Union |
Structure |
10 Inch Flanged Gate Valve |
Installation procedure of gate valve:
1. According to the design, the vertical centerline of the water outlet and the bottom height line of the gate valve are marked, and the deviation requires less than ± 10 mm. At the same time, check whether the center of the lifting hole of the door body is aligned with the support hole retained for the hoist;
2. Lift the gate valve to ensure that it can remain stable and will not shake
3. Remove the gate valve on the wall, adjust the body of the door to adjust the horizontal and vertical (the horizontal and vertical door frame and the door frame of the side groove do not exceed 1/1000), the connecting gate valve frame is embedded, and the second Level castings take effective sealing measures to ensure that there is no gap between the gate valve frame and the structure.
http://www.gy-valve.net/